A quick guide to LRV specification and lifts
Lift design is ever-evolving and without a doubt, specifying the right surface or object reflectance for lift cabin finishes is key to designing a building that everyone can use – especially the visually impaired.
What is LRV?
It is important not to confuse light reflectance value (LRV) with colour intensity. LRV measures how much light a colour reflects and absorbs. It runs from 0% to 100%.
Zero is assumed to be an absolute black and 100% an assumed perfectly reflective white. Approximately speaking, the average blackest black has an LRV of 5% and the whitest white at 85%. Some yellows can measure up into the ’80s or 90s as well.
Why is LRV important?
For the majority of people, colour differences can provide adequate visual contrast. However, this is not the case for all building users. People with vision impairments often distinguish surfaces by the amount of light they reflect. The greater the difference between LRV and adjacent materials, the more likely the difference in surfaces will be identified, for example enabling the visually impaired to identify controls or distinguish lift car doors from adjacent walls.
Examples of where visual contrast and LRV difference between finishes can be required in lifts:
- The call panel should be easily distinguishable from its background.
- The floor area outside the lift and lift car doors should be visually distinguishable from the adjoining walls.
- Lighting and surfaces within the lift car should minimise glare, reflection, confusing shadows and pools of light and dark.
- Lights adjacent to control panels are not recommended because they could make it difficult for people to read controls.
What do the building regulations and design guidance say?
As far as building regulations are concerned, and where compliance with Technical Guidance Document Part M 2010 is required, it is important to ensure that elements of a building do not pose a risk to people with vision impairments.
References for LRV tend to be in Building standards and design guidelines rather than specific lift standards. Below are some of the references to contrast and LRV that you should consider.
Part M - General guidance
Contrast visually, when used to indicate the visual perception of one element of the building, or fitting within the building against another means that the difference in light reflective value between the two surfaces is greater than 30 points. Where illuminance on surface is greater than 200 lux, a difference in light reflective value should be a minimum of 20 points. Where door opening furniture projects beyond the face of the door or otherwise creates enhance differentiation and shade a minimum difference in LRV of 15 points is considered adequate (1)
General requirements for lifting devices – Design Considerations
3.28d - All call and control buttons contrast visually with the surrounding face place, and the face plate similarly contrasts with the surface on which it is mounted.
3.28e – The floor of the lifting device should not be of a dark colour and should have frictionless qualities similar to or higher than, the floor of the landing;
Technical Handbook (Scotland)
States that lift doors, handrails and controls should contrast visually with surrounding surfaces (no reference to actual values).
BS 8300-2:2016
Advises doors and floors to contrast visually with their surroundings – no reference to values.
Lifts Standards
The only lift standard citing LRV are passenger lift standards (> 0.15m/s) within BS EN 81-70:2018 - Accessibility to lifts for persons, including persons with disability. Here the onus is on the customer to comply with lift identification to the background, and faceplates to its surrounding.
Conclusion
Increasingly there are more requests for colour considerations as awareness grows over visual impairments and increasing awareness of how dementia affects visual perception.
1) For further information, reference should be made to Colour, contrast and perception – Design guidance for internal build environments – Reading University.
--Stannahlifts 11:47, 20 May 2022 (BST)
Featured articles and news
A must-attend event for the architecture industry.
Caroline Gumble to step down as CIOB CEO in 2025
After transformative tenure take on a leadership role within the engineering sector.
RIDDOR and the provisional statistics for 2023 / 2024
Work related deaths; over 50 percent from constructuon and 50 percent recorded as fall from height.
Solar PV company fined for health and safety failure
Work at height not properly planned and failure to take suitable steps to prevent a fall.
The term value when assessing the viability of developments
Consultation on the compulsory purchase process, compensation reforms and potential removal of hope value.
Trees are part of the history of how places have developed.
The increasing costs of repair and remediation
Highlighted by regulator of social housing, as acceleration plan continues.
Free topic guide on mould in buildings
The new TG 26/2024 published by BSRIA.
Greater control for LAs over private rental selective licensing
A brief explanation of changes with the NRLA response.
Practice costs for architectural technologists
Salary standards and working out what you’re worth.
The Health and Safety Executive at 50
And over 200 years of Operational Safety and Health.
Thermal imaging surveys a brief intro
Thermal Imaging of Buildings; a pocket guide BG 72/2017.
Internally insulating a historical building
An experimental DIY approach using mineral thermal lime plaster.
Tree species selection for green infrastructure: A guide for specifiers.
The future of the Grenfell Tower site
Principles, promises, recommendations and a decision expected in February 2025.